Low-temperature air channel testing of thermally bonded PVC geomembrane seams

T. D. Stark, H. Choi and R. W. Thomas
January 1, 2004
Geosynthetics International, 2004, 11, No. 6

The objective of this paper is to develop a procedure for air channel testing of dualtrack thermal seams at low sheet temperatures and recommendations for reducing destructive testing of field PVC geomembrane seams. Thus the proposed relationship and equation allow the seam peel strength to be determined from the field air channel testing without conducting destructive tests.