Leak Testing Mechanical Attachments
- Cannot conduct electronic leak locate survey near metalattachments because of interference so need some other type of testing ofattachments
- Place ballast tubes around penetration, inject airbelow geomembrane, soap the attachment, and watch for bubbles along or aroundattachment
- Thermal imaging – not tried yet but possibly effective onsunny day to measure cooler air being pumped below geomembrane and exiting atleak(s) along attachment
- Vacuum below the geomembrane in tank or attachment and listen for vacuum sound along attachment
- Vacuum Acoustic Leak Identification (VALID) method – apply vacuum between primary and secondary geomembranes and listen for vacuum soundalong attachments; tests both geomembranes; the top surface of the geomembrane is scanned with ultrasonic microphones that can detect distinctive sounds of a vacuum leak.
- Smoke Test – smoke exits at attachment surrounded by ballast tubes
- Spark test with material embed but cannot be used at landfills and oil and gas sites
- Vacuum boxes for strips and corners but limited because not straight segments for box
- Dye test – divers places dye along attachment or concrete joint and see if dye disappears into attachment or crack (see video)
To see full document, please click on Download button.
To see full document, please click on Download button.
- Changes in liquid/water level but must show that change in level is not due to evaporation
- Seepage around pond/containment facility
- Contaminant detection in groundwater monitoring well(s)
- Pressure transducer – placed in stilling well on opposite sides or in LDZ sump show different liquid pressures
- Add chloride to liquid and conduct subsequent geophysical testing to detect chloride outside of facility
- Add dye to liquid and monitor adjacent wells
- Measure flow in Leak Detection Zone (LDZ) if present
To see full document, please click on Download button.
1. Estimating remaining service life is important for owner’s replacement and budgeting purposes. This is gaining popularity in Australia, South America, and west and southwestern portions of the United States. As a result, a main objective of this White Paper is to educate engineers and owners on how to design, specify, and include sample coupons in their designs and installations, respectively. Most of this White Paper focuses on new projects except for the last section which focuses on old projects.
To see full document, please click on Download button.